Test Code IRONPP Iron Profile
Additional Codes
EPIC: LAB9642
Performing Laboratory
St. Joseph Hospital
Methodology & Use
Timed Bichromatic End Point
Measurements of serum iron and iron binding capacity are typically used in the diagnosis and monitoring of iron deficiency anemia and chronic inflammatory disorders.
Specimen Requirements
Preferred: Plasma
Draw blood in a light green-top (lithium heparin gel) tube. (Hemolyzed specimen is not acceptable.) Centrifuge and separate plasma from cells within 2 hours of collection, and send 1 mL of lithium heparin plasma refrigerated.
Note: Label specimen as “plasma”.
Acceptable: Serum
Draw blood in a plain, red-top tube or a serum gel tube. (Hemolyzed specimen is not acceptable.) Centrifuge and separate serum from cells within 2 hours of collection and send 1 mL of serum refrigerated.
Note: Label specimen as “serum”
Specimens are stable for up to 7 days at 4°C.
Reference Values
IRON: Male: 61 - 157 µg/dL Female: 37 - 145 ug/dL
TIBC: 250-450 ug/dL
UIBC: 112 - 347 ug/dL
Iron Saturation: 15 - 50%
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
83540; 83550