Sign in →

Test Code RALB1 Albumin, Random, Urine


Specimen Required


Only orderable as part of a profile. For more information see:

-ALBR / Albumin, Random, Urine

-RALB / Albumin, Random, Urine.

 

Supplies: Sarstedt 5 mL Aliquot Tube (T914)

Specimen Volume: 5 mL

Collection Instructions:

1. Collect a random urine specimen.

2. No preservative.


Useful For

Assessing the potential for early onset of nephropathy in diabetic patients using random urine specimens

Method Name

Only orderable as part of a profile. For more information see:

-ALBR / Albumin, Random, Urine

-RALB / Albumin, Random, Urine.

  

Immunoturbidity

Reporting Name

Albumin, Random, U

Specimen Type

Urine

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Urine Refrigerated (preferred) 7 days
  Ambient  7 days
  Frozen  7 days

Reject Due To

All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Clinical Information

Diabetic nephropathy is a complication of diabetes and is characterized by proteinuria (normal urinary albumin excretion is <30 mg/day; overt proteinuria is >300 mg/day). Before overt proteinuria develops, albumin excretion increases in those diabetic patients who are destined to develop diabetic nephropathy. Therapeutic maneuvers (eg, aggressive blood pressure maintenance, particularly with angiotensin-converting enzyme inhibitors; aggressive blood sugar control; and possibly decreased protein intake) can significantly delay, or possibly prevent, development of nephropathy. Thus, there is a need to identify small, but abnormal, increases in the excretion of urinary albumin (in the range of 30-300 mg/day, ie, microalbuminuria).

 

The National Kidney Foundation guidelines for the management of patients with diabetes and microalbuminuria recommend that all type 1 diabetic patients older than 12 years and all type 2 diabetic patients younger than 70 years have their urine tested for microalbuminuria yearly when they are under stable glucose control.(1)

 

The preferred specimen is a 24-hour collection, but a random collection is acceptable. Studies have shown that correcting albumin for creatinine excretion rates has similar discriminatory value with respect to diabetic renal involvement. The albumin:creatinine ratio from a random urine specimen is also considered a valid screening tool.(2) Several studies have addressed whether the specimen needs to be a fasting urine, an exercised urine, or an overnight urine specimen. These studies have shown that the first-morning urine specimen is less sensitive, but more specific.

 

Studies also have shown that microalbuminuria is a marker of generalized vascular disease and is associated with stroke and heart disease.

Reference Values

Only orderable as part of a profile. For more information see:

-ALBR / Albumin, Random, Urine

-RALB / Albumin, Random, Urine.

 

Males: <17 mg/g creatinine

Females: <25 mg/g creatinine

Day(s) Performed

Monday through Sunday

Report Available

1 day

Specimen Retention Time

7 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

82043

LOINC Code Information

Test ID Test Order Name Order LOINC Value
RALB1 Albumin, Random, U 9318-7

 

Result ID Test Result Name Result LOINC Value
RALB1 Albumin, Random, U 89999-7